Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT)

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

17 Scopus citations

Abstract

New advances in catheter technology and remote actuation for minimally invasive procedures are continuously increasing the demand for better x-ray imaging technology. The new x-ray high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) detector offers high resolution and real-time image-guided capabilities which are unique when compared with commercially available detectors. This detector consists of a 300 μn CsI input phosphor coupled to a dual stage GEN2 micro-channel plate light image intensifier (LII), followed by minifying fiber-optic taper coupled to a CCD chip. The HS-MAF detector image array is 1024×1024 pixels, with a 12 bit depth capable of imaging at 30 frames per second. The detector has a round field of view with 4 cm diameter and 35 microns pixels. The LII has a large variable gain which allows usage of the detector at very low exposures characteristic of fluoroscopic ranges while maintaining very good image quality. The custom acquisition program allows real-time image display and data storage. We designed a set of in-vivo experimental interventions in which placement of specially designed endovascular stents were evaluated with the new detector and with a standard x-ray image intensifier (XII). Capabilities such fluoroscopy, angiography and ROI-CT reconstruction using rotational angiography data were implemented and verified. The images obtained during interventions under radiographic control with the HS-MAF detector were superior to those with the XII. In general, the device feature markers, the device structures, and the vessel geometry were better identified with the new detector. High-resolution detectors such as HS-MAF can vastly improve the accuracy of localization and tracking of devices such stents or catheters.

Original languageEnglish
Title of host publicationMedical Imaging 2008 - Visualization, Image-Guided Procedures, and Modeling
DOIs
StatePublished - 2008
EventMedical Imaging 2008 - Visualization, Image-Guided Procedures, and Modeling - San Diego, CA, United States
Duration: Feb 17 2008Feb 19 2008

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6918
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2008 - Visualization, Image-Guided Procedures, and Modeling
Country/TerritoryUnited States
CitySan Diego, CA
Period02/17/0802/19/08

Keywords

  • Cone-beam computed tomography
  • Endovascular image-guided interventions
  • High-resolution fluoroscopy
  • Micro-angiographic fluoroscope
  • Region-of-interest micro-angiography
  • ROI-CT