Skip to main navigation Skip to search Skip to main content

Impact of anode evaporation on the anode region of a high-intensity argon arc

  • University of Minnesota Twin Cities

Research output: Contribution to journalArticlepeer-review

39 Scopus citations

Abstract

Experimental studies of a free-burning, high-intensity argon arc operated at 800 Torr with a solid, molten, or resolidified copper anode demonstrate that the cathode region is not affected by Cu vapor from the anode. Also Cu vapor concentrations in the arc core (beyond 1 mm from the anode surface) are negligible. In contrast, there is a strong effect of the Cu vapor on the anode region of the arc. The arc fringes become electrically conducting due to the presence of Cu vapor, resulting in a flattening of the current density distribution and a corresponding drop of the temperature in the arc core. At the same time, the overall arc voltage shows a slight drop (<1 V). In the case of the resolidified anode, the overall arc voltage increases, which seems to be associated with the distribution of the stagnation flow in front of the anode due to a dip in the center of the anode.

Original languageEnglish
Pages (from-to)175-182
Number of pages8
JournalPlasma Chemistry and Plasma Processing
Volume5
Issue number2
DOIs
StatePublished - Jun 1985

Keywords

  • effect of anode vapor
  • Free-burning arcs
  • spectroscopy

Fingerprint

Dive into the research topics of 'Impact of anode evaporation on the anode region of a high-intensity argon arc'. Together they form a unique fingerprint.