T1 - Image acquisition, geometric correction and display of images from a 2x2 x-ray detector array based on electron multiplying charge coupled device (EMCCD) technology
AU - Swetadri Vasan, S. N.
AU - Sharma, P.
AU - Ionita, Ciprian N.
AU - Titus, A. H.
AU - Cartwright, A. N.
AU - Bednarek, D. R.
AU - Rudin, S.
PY - 2013
Y1 - 2013
N2 - A high resolution (up to 11.2 lp/mm) x-ray detector with larger field of view (8.5 cm x 8.5 cm) has been developed. The detector is a 2 x 2 array of individual imaging modules based on EMCCD technology. Each module outputs a frame of size 1088 x 1037 pixels, each 12 bits. The frames from the 4 modules are acquired into the processing computer using one of two techniques. The first uses 2 CameraLink communication channels with each carrying information from two modules, the second uses a application specific custom integrated circuits, the Multiple Module Multiplexer Integrated Circuit (MMMIC), 3 of which are used to multiplex the data from 4 modules into one CameraLink channel. Once the data is acquired using either of the above mentioned techniques, it is decoded in the graphics processing unit (GPU) to form one single frame of size 2176 x 2074 pixels each 16 bits. Each imaging module uses a fiber optic taper coupled to the EMCCD sensor. To correct for mechanical misalignment between the sensors and the fiber optic tapers and produce a single seamless image, the images in each module may be rotated and translated slightly in the x-y plane with respect to each other. To evaluate the detector acquisition and correction techniques, an aneurysm model was placed over an anthropomorphic head phantom and a coil was guided into the aneurysm under fluoroscopic guidance using the detector array. Image sequences before and after correction are presented which show near-seamless boundary matching and are well suited for fluoroscopic imaging.
AB - A high resolution (up to 11.2 lp/mm) x-ray detector with larger field of view (8.5 cm x 8.5 cm) has been developed. The detector is a 2 x 2 array of individual imaging modules based on EMCCD technology. Each module outputs a frame of size 1088 x 1037 pixels, each 12 bits. The frames from the 4 modules are acquired into the processing computer using one of two techniques. The first uses 2 CameraLink communication channels with each carrying information from two modules, the second uses a application specific custom integrated circuits, the Multiple Module Multiplexer Integrated Circuit (MMMIC), 3 of which are used to multiplex the data from 4 modules into one CameraLink channel. Once the data is acquired using either of the above mentioned techniques, it is decoded in the graphics processing unit (GPU) to form one single frame of size 2176 x 2074 pixels each 16 bits. Each imaging module uses a fiber optic taper coupled to the EMCCD sensor. To correct for mechanical misalignment between the sensors and the fiber optic tapers and produce a single seamless image, the images in each module may be rotated and translated slightly in the x-y plane with respect to each other. To evaluate the detector acquisition and correction techniques, an aneurysm model was placed over an anthropomorphic head phantom and a coil was guided into the aneurysm under fluoroscopic guidance using the detector array. Image sequences before and after correction are presented which show near-seamless boundary matching and are well suited for fluoroscopic imaging.
UR - https://www.scopus.com/pages/publications/84878277981
U2 - 10.1117/12.2006280
DO - 10.1117/12.2006280
M3 - Conference contribution
AN - SCOPUS:84878277981
SN - 9780819494429
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2013
T2 - Medical Imaging 2013: Physics of Medical Imaging
Y2 - 11 February 2013 through 14 February 2013
ER -