Skip to main navigation Skip to search Skip to main content

Health-related quality of life consequences of implantable cardioverter defibrillators: Results from MADIT II

  • Katia Noyes
  • , Ethan Corona
  • , Jack Zwanziger
  • , W. Jackson Hall
  • , Hongwei Zhao
  • , Hongkun Wang
  • , Arthur J. Moss
  • , Andrew W. Dick
  • University of Rochester
  • University of Illinois at Chicago
  • University of Virginia
  • RAND Corporation

Research output: Contribution to journalArticlepeer-review

55 Scopus citations

Abstract

BACKGROUND:: Implantable cardioverter defibrillators (ICDs) improve survival and extend lives of patients with severe heart disease. OBJECTIVE:: We sought to evaluate the impact of ICDs on health-related quality of life (HRQOL) during the first 3 years after implantation. SUBJECTS:: A total of 1089 patients from the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) were randomized to an ICD or medical treatment only. MEASURES:: Health Utility Index (HUI3) at baseline, 3, 12, 24, and 36 months following randomization; survival data. RESEARCH DESIGN:: We constructed mean profiles of HRQOL for living patients, estimated overall quality-adjusted life years (QALYs), separately by treatment arm, and calculated cumulative QALY gains/losses as the difference between the areas under the treatment specific HRQOL profiles. Multivariate fixed effect regression models were developed to impute the missing HRQOL data using baseline patient characteristics (age, gender, treatment, HUI3 score, diabetes, diuretics use, and NYHA class). Bootstrapped standard errors were calculated for the estimated differences in HRQOL gains/losses between treatment arms. Similarly, we performed subgroup analyses (by gender, age, and baseline NYHA class, blood urine nitrogen, ejection fraction, and QRS). RESULTS:: There were no differences in QALYs loss for living patients by treatment group (ĝ̂'0.037, P ≤ 0.64) or in overall QALYs loss by treatment group (0.043, P ≤ 0.37) over 3 years. In subgroup analysis, female subjects demonstrated a trend towards greater survival benefit (0.298, P ≤ 0.07) and overall QALYs (0.261, P ≤ 0.14). CONCLUSIONS:: Adverse effects of the ICD on HRQOL together with lower HRQOL among survivors may offset the 3-year survival benefits of ICDs.

Original languageEnglish
Pages (from-to)377-385
Number of pages9
JournalMedical Care
Volume45
Issue number5
DOIs
StatePublished - May 2007

Keywords

  • Health-related quality-of-life
  • Implantable cardioverter defibrillator
  • MADIT II
  • Survival

Fingerprint

Dive into the research topics of 'Health-related quality of life consequences of implantable cardioverter defibrillators: Results from MADIT II'. Together they form a unique fingerprint.

Cite this