Skip to main navigation Skip to search Skip to main content

Hairpin RF resonators for MR imaging transceiver arrays with high inter-channel isolation and B1 efficiency at ultrahigh field 7 T

  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Electromagnetic decoupling among a close-fitting or high-density transceiver RF array elements is required to maintain the integrity of the magnetic flux density from individual channel for enhanced performance in detection sensitivity and parallel imaging. High-impedance RF coils have demonstrated to be a prominent design method to circumvent these coupling issues. Yet, inherent characteristics of these coils have ramification on the B1 field efficiency and SNR. In this work, we propose a hairpin high impedance RF resonator design for highly decoupled multichannel transceiver arrays at ultrahigh magnetic fields. Due to the high impedance property of the hairpin resonators, the proposed transceiver array can provide high decoupling performance without using any dedicated decoupling circuit among the resonant elements. Because of elimination of lumped inductors in the resonator circuit, higher B1 field efficiency in imaging subjects can be expected. In order to validate the feasibility of the proposed hairpin RF coils, systematical studies on decoupling performance, field distribution, and SNR are performed, and the results are compared with those obtained from existing high-impedance RF coil, e.g., “self-decoupled RF coil”. To further investigate its performance, an 8-channel head coil array using the proposed hairpin resonators loaded with a cylindrical phantom is designed, demonstrating a 19 % increase of the B1+ field intensity compared to the self-decoupled coils at 7 T. Furthermore, the characteristics of the hairpin RF coils are evaluated using a more realistic human head voxel model numerically. The proposed hairpin RF coil provides excellent decoupling performance and superior RF magnetic field efficiency compared to the “self-decoupled” high impedance coils. Bench test of a pair of fabricated hairpin coils prove to be in good accordance with numerical results.

Original languageEnglish
Article number107321
JournalJournal of Magnetic Resonance
Volume345
DOIs
StatePublished - Dec 2022

Keywords

  • High/low-impedance coil
  • Magnetic resonance imaging
  • Mutual decoupling
  • Parallel MRI
  • Ultra-high field

Fingerprint

Dive into the research topics of 'Hairpin RF resonators for MR imaging transceiver arrays with high inter-channel isolation and B1 efficiency at ultrahigh field 7 T'. Together they form a unique fingerprint.

Cite this