Skip to main navigation Skip to search Skip to main content

Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

13 Scopus citations

Abstract

The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick Csl) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300-micron thick Csl). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks.

Original languageEnglish
Title of host publicationMedical Imaging 2010
Subtitle of host publicationPhysics of Medical Imaging
EditionPART 1
DOIs
StatePublished - 2010
EventMedical Imaging 2010: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 15 2010Feb 18 2010

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
NumberPART 1
Volume7622
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2010: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period02/15/1002/18/10

Keywords

  • DQE
  • FPD
  • GDQE
  • GMTF
  • MAF
  • MTF

Fingerprint

Dive into the research topics of 'Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics'. Together they form a unique fingerprint.

Cite this