Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural ventilation

  • Dalian University of Technology
  • Virginia Polytechnic Institute and State University

Research output: Contribution to journal › Article › peer-review

32 Scopus citations

Abstract

Natural ventilation is an effective strategy to control thermal comfort in buildings, and can be enhanced depending on the window style. The combination of natural ventilation and window can also facilitate the removal or dilution of gaseous pollutants from indoor sources in newly decorated buildings. However, the windows on the same facade may cause gaseous pollutant cross-transmission during single-sided natural ventilation between households on different floors close to the source. Although some research has focused on the pollutant cross-transmission in buildings, the simplification of windows into rectangular openings often affects accurate knowledge of pollutant transmission characteristics. Therefore, this investigation explored gaseous pollutant cross-transmission through real windows during single-sided, buoyancy-driven ventilation in a multistory building. Six types of windows were modeled for the indoor pollutant of gaseous formaldehyde (HCHO). Computational fluid dynamics (CFD) was utilized to solve characteristics of pollutant transmission inside and outside the multistory building. The results indicated that the ventilation rates, thermal profiles and pollutant transmission inside and outside the building varied for each window type, although the open window areas were identical. The re-entry ratio of exhausted air entering upper floors and the infection risk of epidemic viruses caused by airborne cross-transmission was sensitive to ventilation rates and window configurations, while the sensitivities for window configurations varied case by case. The comparisons also revealed that the specification of ambient temperature and pollutant release rate ultimately did not affect the evaluation of pollutant cross-transmission using CFD.

Original languageEnglish
Pages (from-to)325-340
Number of pages16
JournalEnergy and Buildings
Volume153
DOIs
StatePublished - Oct 15 2017

Keywords

  • CFD
  • Cross-transmission
  • Gaseous pollutant
  • Natural ventilation
  • Window configuration

Fingerprint

Dive into the research topics of 'Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural ventilation'. Together they form a unique fingerprint.

Cite this