TY - GEN
T1 - Experimental evaluation of contact-less hand tracking systems for tele-operation of surgical tasks
AU - Kim, Yonjae
AU - Kim, Peter C.W.
AU - Selle, Rebecca
AU - Shademan, Azad
AU - Krieger, Axel
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/9/22
Y1 - 2014/9/22
N2 - This paper reports an evaluation of contact-less hand tracking sensors for the use of tele-operation, in particular for surgical robotics applications. Two hand tracking systems are investigated: 3Gear Systems interface with the Microsoft Kinect™ sensor, and the Leap Motion sensor system. This paper reports an experimental evaluation and comparison of the two systems range, static positioning error, trajectory accuracy of single finger and hand motions, and latency. Latency and trajectory accuracy were found superior using the Leap system. Kinect™/3Gear was found superior when larger range and gesture control are necessary. 3Gear was used in a simulated surgical positioning task and demonstrated an average translational accuracy of 6.2mm. Given the data we have collected, we conclude that neither system, at present, possesses the high level of accuracy and robustness over the required range that would be a prerequisite for use as a medical robotics master.
AB - This paper reports an evaluation of contact-less hand tracking sensors for the use of tele-operation, in particular for surgical robotics applications. Two hand tracking systems are investigated: 3Gear Systems interface with the Microsoft Kinect™ sensor, and the Leap Motion sensor system. This paper reports an experimental evaluation and comparison of the two systems range, static positioning error, trajectory accuracy of single finger and hand motions, and latency. Latency and trajectory accuracy were found superior using the Leap system. Kinect™/3Gear was found superior when larger range and gesture control are necessary. 3Gear was used in a simulated surgical positioning task and demonstrated an average translational accuracy of 6.2mm. Given the data we have collected, we conclude that neither system, at present, possesses the high level of accuracy and robustness over the required range that would be a prerequisite for use as a medical robotics master.
UR - https://www.scopus.com/pages/publications/84929151031
U2 - 10.1109/ICRA.2014.6907364
DO - 10.1109/ICRA.2014.6907364
M3 - Conference contribution
AN - SCOPUS:84929151031
T3 - Proceedings - IEEE International Conference on Robotics and Automation
SP - 3502
EP - 3509
BT - Proceedings - IEEE International Conference on Robotics and Automation
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 IEEE International Conference on Robotics and Automation, ICRA 2014
Y2 - 31 May 2014 through 7 June 2014
ER -