Skip to main navigation Skip to search Skip to main content

Evaluation of wheelchair tire rolling resistance using dynamometer-based coast-down tests

  • Andrew M. Kwarciak
  • , Mathew Yarossi
  • , Arvind Ramanujam
  • , Trevor A. Dyson-Hudson
  • , Sue Ann Sisto
  • Kessler Foundation
  • Rutgers - The State University of New Jersey, Newark

Research output: Contribution to journalArticlepeer-review

55 Scopus citations

Abstract

The objective of this study was to compare the rolling resistance of four common manual wheelchair tires (two pneumatic and two airless solid) and the solid tires used on a commercially available force- and moment-sensing wheel. Coast-down tests were performed with a wheelchair positioned on a two-drum dynamometer. Within each of three load conditions, tire type had a significant effect on rolling resistance (p < 0.001). The pneumatic tires had smaller rolling resistances and were less affected by load increases than the solid tires. Within the two tire types, higher air pressure or firmness and lower profile tread corresponded to less rolling resistance. Wheelchair users, clinicians, and researchers must consider the effect of tire type on wheelchair rolling resistance when selecting a manual wheelchair tire.

Original languageEnglish
Pages (from-to)931-938
Number of pages8
JournalJournal of Rehabilitation Research and Development
Volume46
Issue number7
DOIs
StatePublished - 2009

Keywords

  • Coast-down test
  • Dynamometer
  • Inflation pressure
  • Manual wheelchair
  • Pneumatic tire
  • Rehabilitation
  • Rolling resistance
  • Solid tire
  • Tire type
  • Wheeled mobility

Fingerprint

Dive into the research topics of 'Evaluation of wheelchair tire rolling resistance using dynamometer-based coast-down tests'. Together they form a unique fingerprint.