Skip to main navigation Skip to search Skip to main content

Evaluation of embolic deflection device using optical particle tracking

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Scopus citations

Abstract

Trans-aortic valve replacement is a new endovascular procedure which has started to be used routinely in cardiac interventional suites. During such procedures a stent-like device containing new aortic valves is placed over the damaged ones, possibly causing calcifications to be dislodged and released in arteries leading to stroke. To prevent such events, new devices are being developed to provide distal protection to the brain supplying arteries. Currently there is a need to evaluate such device efficacy in a repeatable manner. We are proposing and investigating such a method based on particle optical tracking. We simulated such protective devices using two porous screens (150 and 200 μm pore size) which were placed in an arterial bifurcation phantom connected to a clinically relevant flow loop. A mask was acquired and gold embolic particles (100-300μm) were injected at a steady rate using a motorized injector. Optical images with 2 ms exposure were acquired at 30 fps. Images were subtracted, thresholded and filtered using a 5x5 median filter. ROI's were drawn over the main and bifurcating arteries and a particle counting algorithm was used to estimate particle flow rates in each artery for each run. The unprotected and the two protected cases were evaluated. Before filter placement, the particle flow rate was 60 and 40 %, respectively, of the main artery. After the filter placement, the particle flow rate in the protected branch was 4% and 8% of the particle flow rate in the main artery. We present a method to assess the efficacy of such devices using an optical particle tracking and counting technique.

Original languageEnglish
Title of host publicationMedical Imaging 2013
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
DOIs
StatePublished - 2013
EventMedical Imaging 2013: Biomedical Applications in Molecular, Structural, and Functional Imaging - Lake Buena Vista, FL, United States
Duration: Feb 10 2013Feb 13 2013

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume8672
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2013: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CityLake Buena Vista, FL
Period02/10/1302/13/13

Keywords

  • Embolic deflection device
  • Optical particle tracking
  • Trans-aortic valve replacement

Fingerprint

Dive into the research topics of 'Evaluation of embolic deflection device using optical particle tracking'. Together they form a unique fingerprint.