Endocochlear Potential and Potassium Concentration Recording in Minipig Cochlea

  • Weiwei GUO
  • , Chen Lei
  • , Li Dengke
  • , Sun Wei
  • , Yang Shiming
  • General Hospital of People's Liberation Army
  • China Agricultural University

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Objective: To record the endocochlear potential (EP) and calculate potassium concentration [K +] in Minipig cochleae. Methods: We used multi-barreled electrodes to measure the EP and the potential, [K +]. EP and potassium electrode recording were made in 9 cochleae from 5 minipigs to get normal EP values. Results: The average EP value in the cochlea from the minipigs was 77.3 ± 14 mV. The average [K +] for the minipigs was 147.1 ± 13 mM. Conclusions: The EP and potential, [K +] in minipigs are lower than in the human and rodents. This may be the reason why porcine ABR thresholds are slightly higher than humans and rodents.

Original languageEnglish
Pages (from-to)103-105
Number of pages3
JournalJournal of Otology
Volume7
Issue number2
DOIs
StatePublished - Dec 2012

Keywords

  • endocochlear potential
  • minipig
  • potassium secretion
  • stria vascularis