Abstract

Parametric imaging maps (PIMa's) derived from digital subtraction angiography (DSA) for the cerebral arterial flow assessment in clinical settings have been proposed, but experiments have yet to determine the reliability of such studies. For this study, we have observed the effects of different injection techniques on PIMa's. A flow circuit set to physiologic conditions was created using an internal carotid artery phantom. PIMa's were derived for two catheter positions, two different contrast bolus injection volumes (5ml and 10 ml), and four injection rates (5, 10, 15 and 20 ml/s). Using a gamma variate fitting approach, we derived PIMa's for mean-transit-time (MTT), time-to-peak (TTP) and bolus-arrivaltime (BAT). For the same injection rates, a larger bolus resulted in an increased MTT and TTP, while a faster injection rate resulted in a shorter MTT, TTP, and BAT. In addition, the position of the catheter tip within the vasculature directly affected the PIM. The experiment showed that the PIM is strongly correlated with the injection conditions, and, therefore, they have to be interpreted with caution. PIM images must be taken from the same patient to be able to be meaningfully compared. These comparisons can include pre- and post-treatment images taken immediately before and after an interventional procedure or simultaneous arterial flow comparisons through the left and right cerebral hemispheres. Due to the strong correlation between PIM and injection conditions, this study indicates that this assessment method should be used only to compare flow changes before and after treatment within the same patient using the same injection conditions.

Original languageEnglish
Title of host publicationMedical Imaging 2014
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
PublisherSPIE
ISBN (Print)9780819498311
DOIs
StatePublished - 2014
EventMedical Imaging 2014: Biomedical Applications in Molecular, Structural, and Functional Imaging - San Diego, CA, United States
Duration: Feb 16 2014Feb 18 2014

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9038
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2014: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period02/16/1402/18/14

Keywords

  • DSA
  • Mean Transit Time
  • MTT
  • Parametric Imaging Maps
  • Time to Peak