Skip to main navigation Skip to search Skip to main content

Effect of displacement restraint on the collapse performance of seismically isolated buildings

  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

43 Scopus citations

Abstract

This study investigates the effect of displacement restraint on the collapse performance of seismically isolated buildings. The displacement restraints considered are stiffening triple Friction Pendulum (FP) bearings and moat walls. The study is based on 6-story perimeter frame seismically isolated buildings designed with special concentrically braced frames (SCBF) and special moment resisting frames (SMF) for a location in California using the minimum criteria of ASCE/SEI 7-10 and ASCE/SEI 7-16 and also using enhanced designs. Results from pushover analysis and nonlinear response history analysis demonstrate that proper designs require a balance between the value of RI for the design of the superstructure and the displacement capacity of the isolators. The paper shows that isolation systems with sufficient displacement capacity before engaging the displacement restraint and a RI factor consistent to that displacement capacity may have an acceptable collapse risk. Values of the design parameters for the superstructure and the displacement capacity and behavior of the isolation system for achieving acceptable collapse risk are presented.

Original languageEnglish
Pages (from-to)2767-2786
Number of pages20
JournalBulletin of Earthquake Engineering
Volume17
Issue number5
DOIs
StatePublished - May 15 2019

Keywords

  • ASCE/SEI 7 standard
  • Collapse probability
  • Displacement restraint
  • Friction pendulum isolator
  • Moat walls
  • Seismic isolation

Fingerprint

Dive into the research topics of 'Effect of displacement restraint on the collapse performance of seismically isolated buildings'. Together they form a unique fingerprint.

Cite this