Skip to main navigation Skip to search Skip to main content

Earthquake simulator testing and evaluation of suspended ceilings: Standard and alternate perimeter installations

  • Miyamoto International
  • Chicago Metallic Corp.
  • Technion-Israel Institute of Technology

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

7 Scopus citations

Abstract

Nonstructural components comprise an integral part of the buildings. Due to their high inventory cost and effect on loss of operation, they are often critical to a buildings' seismic performance. Suspended ceilings are one of the most widely used nonstructural components. They are a standard feature of modern office building. Past earthquakes have demonstrated the susceptibility of suspended ceilings to failure during seismic events. To address this vulnerability, design codes have developed specific installation criteria for suspended ceilings. However, these units are very difficult to analyze. Thus, there is limited data available to assess the efficacy of such installation. Furthermore, ceiling manufacturers have been investigating and have developed alternate and more time-efficient installation techniques. In lieu of analysis, earthquake simulation testing can be employed to assess the seismic performance of ceilings and to qualify comparatively the alternate perimeter installation.

Original languageEnglish
Title of host publicationProceedings of the 2008 Structures Congress - Structures Congress 2008
Subtitle of host publicationCrossing the Borders
PublisherAmerican Society of Civil Engineers (ASCE)
ISBN (Print)9780784410165
DOIs
StatePublished - 2008
Event2008 Structures Congress - Structures Congress 2008: Crossing the Borders - Vancouver, BC, Canada
Duration: Apr 24 2008 → Apr 26 2008

Publication series

NameProceedings of the 2008 Structures Congress - Structures Congress 2008: Crossing the Borders
Volume314

Conference

Conference2008 Structures Congress - Structures Congress 2008: Crossing the Borders
Country/TerritoryCanada
CityVancouver, BC
Period04/24/08 → 04/26/08

Fingerprint

Dive into the research topics of 'Earthquake simulator testing and evaluation of suspended ceilings: Standard and alternate perimeter installations'. Together they form a unique fingerprint.