T1 - Dose reduction by moving a region of interest (ROI) beam attenuator to follow a moving object of interest
AU - Panse, Ashish S.
AU - Swetadri Vasan, S. N.
AU - Jain, A.
AU - Bednarek, D. R.
AU - Rudin, S.
PY - 2012
Y1 - 2012
N2 - Region-of-interest (ROI) fluoroscopy takes advantage of the fact that most neurovascular interventional activity is performed in only a small portion of an x-ray imaging field of view (FOV). The ROI beam filter is an attenuating material that reduces patient dose in the area peripheral to the object of interest. This project explores a method of moving the beam-attenuator aperture with the object of interest such that it always remains in the ROI. In this study, the ROI attenuator, which reduces the dose by 80% in the peripheral region, is mounted on a linear stage placed near the xray tube. Fluoroscopy is performed using the Microangiographic Fluoroscope (MAF) which is a high-resolution, CCD-based x-ray detector. A stainless-steel stent is selected as the object of interest, and is moved across the FOV and localized using an object-detection algorithm available in the IMAQ Vision package of LabVIEW. The ROI is moved to follow the stent motion. The pixel intensities are equalized in both FOV regions and an adaptive temporal filter dependent on the motion of the object of interest is implemented inside the ROI. With a temporal filter weight of 5% for the current image in the peripheral region, the SNR measured is 47.8. The weights inside the ROI vary between 10% and 33% with a measured SNR of 57.9 and 35.3 when the object is stationary and moving, respectively. This method allows patient dose reduction as well as maintenance of superior image quality in the ROI while tracking the object.
AB - Region-of-interest (ROI) fluoroscopy takes advantage of the fact that most neurovascular interventional activity is performed in only a small portion of an x-ray imaging field of view (FOV). The ROI beam filter is an attenuating material that reduces patient dose in the area peripheral to the object of interest. This project explores a method of moving the beam-attenuator aperture with the object of interest such that it always remains in the ROI. In this study, the ROI attenuator, which reduces the dose by 80% in the peripheral region, is mounted on a linear stage placed near the xray tube. Fluoroscopy is performed using the Microangiographic Fluoroscope (MAF) which is a high-resolution, CCD-based x-ray detector. A stainless-steel stent is selected as the object of interest, and is moved across the FOV and localized using an object-detection algorithm available in the IMAQ Vision package of LabVIEW. The ROI is moved to follow the stent motion. The pixel intensities are equalized in both FOV regions and an adaptive temporal filter dependent on the motion of the object of interest is implemented inside the ROI. With a temporal filter weight of 5% for the current image in the peripheral region, the SNR measured is 47.8. The weights inside the ROI vary between 10% and 33% with a measured SNR of 57.9 and 35.3 when the object is stationary and moving, respectively. This method allows patient dose reduction as well as maintenance of superior image quality in the ROI while tracking the object.
KW - adaptive temporal filtering
KW - Dose reduction
KW - object tracking
KW - Region-of-interest (ROI) fluoroscopy
UR - https://www.scopus.com/pages/publications/84860359532
U2 - 10.1117/12.911136
DO - 10.1117/12.911136
M3 - Conference contribution
AN - SCOPUS:84860359532
SN - 9780819489623
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2012
T2 - Medical Imaging 2012: Physics of Medical Imaging
Y2 - 5 February 2012 through 8 February 2012
ER -