Skip to main navigation Skip to search Skip to main content

Diagnostic accuracy of hemodynamic assessment of intracranial atherosclerotic stenosis from a single angiographic view: a validation study

  • Jianping Xiang
  • , Lei Zhang
  • , Chenbin Rong
  • , Rong Zou
  • , Yumeng Hu
  • , Yongwei Zhang
  • , Ming Wang
  • , Jens Fiehler
  • , Adnan H. Siddiqui
  • , Jun Wang
  • , Zhongrong Miao
  • , Pengfei Yang
  • , Shu Wan
  • , Jianmin Liu
  • Ltd
  • Changhai Hospital
  • Zhejiang Hospital
  • University of Hamburg
  • General Hospital of People's Liberation Army
  • Capital Medical University

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Background The aim of this study is to assess the feasibility of identifying the hemodynamic status of intracranial atherosclerotic stenosis (ICAS) using angio-based fractional flow (FF) calculated from a single angiographic view, with wire-based FF as the reference standard. Method The study retrospectively recruited 100 ICAS patients who underwent pressure wire measurement and digital subtraction angiography. The AccuICAD software was used to calculate angio-based FF, with the wire-measured value serving as the reference standard for evaluating the accuracy, consistency, and diagnostic performance of angio-based FF. Results The mean±SD value of wire-based FF was 0.77±0.18, while the mean value of angio-based FF was 0.77±0.19. A good correlation between angio-based FF and wire-based FF was evident (r=0.90, P<0.001), with good agreement (mean difference 0.00±0.08). The diagnostic accuracy of angio-based FF and percent diameter stenosis (DS%) were 93.23% versus 72.18%, 91.73% versus 72.93%, and 89.47% versus 78.95% for predicted wire-based FF thresholds of 0.70, 0.75, and 0.80, respectively. The area under the curve (AUC) values for angio-based FF and DS% were 0.975 versus 0.822, 0.970 versus 0.814, and 0.943 versus 0.826 at the respective thresholds, respectively. Conclusion The FF calculated from a single angiographic view can be considered an effective tool for functional assessment of cerebral arterial stenosis.

Original languageEnglish
Article number1372
JournalJournal of NeuroInterventional Surgery
Volume17
Issue number10
DOIs
StatePublished - Oct 1 2025

Keywords

  • Angiography
  • Artery
  • Atherosclerosis
  • Blood Flow
  • Stenosis

Fingerprint

Dive into the research topics of 'Diagnostic accuracy of hemodynamic assessment of intracranial atherosclerotic stenosis from a single angiographic view: a validation study'. Together they form a unique fingerprint.

Cite this