Skip to main navigation Skip to search Skip to main content

Development of enhanced fault-tolerance for a 600 kV impulse generator

  • SUNY Buffalo

Research output: Contribution to journalConference articlepeer-review

Abstract

A Marx Bank is a voltage multiplication system that generates high voltage impulses. A six-stage Marx of low impedance design for AC and DC transmission line surge testing is studied. Six 100 kV, 0.5 μF capacitors are charged in parallel and discharged in series to produce a single shot with 5 to 1000 microsecond impulse waveform with a peak of 600 kV and 15 kJ of energy. Resistor elements in the Marx were destroyed when the impulse generator was discharged into a faulted load, particularly after a sequence of repetitive firings that ended in load breakdown. A bulk ceramic tube resistor was developed through industrial participation to eliminate resistor breakdown. There were no further instances of resistor damage using the bulk ceramics.

Original languageEnglish
Pages (from-to)198-201
Number of pages4
JournalIEEE Conference Record of Power Modulator Symposium
StatePublished - 1996
EventProceedings of the 1996 22nd International Power Modulator Symposium - Boca Raton, FL, USA
Duration: Jun 24 1996Jun 27 1996

Fingerprint

Dive into the research topics of 'Development of enhanced fault-tolerance for a 600 kV impulse generator'. Together they form a unique fingerprint.

Cite this