TY - GEN
T1 - Detection of cigarette smoke inhalations from respiratory signals using reduced feature set
AU - Patil, Yogendra
AU - Lopez-Meyer, Paulo
AU - Tiffany, Stephen
AU - Sazonov, Edward
PY - 2013
Y1 - 2013
N2 - A combination of wearable Respiratory Inductive Plethysmograph and a hand-to-mouth Proximity Sensor (PS) can be used to monitor smoking habits and smoke exposure in cigarette smokers. In our previous work, detection of smoke inhalations was achieved by using a Support Vector Machine (SVM) classifier applied to raw sensor signals with 1503-element feature vectors. This study uses empirically-defined 27 features computed from the sensor signals to reduce the length of vectors. Further reduction in the length of the feature vectors was achieved by a forward feature selection algorithm, identifying from 2 to 16 features most critical for smoke inhalations detection. For individual detection models, the 1503-element feature vectors, 27-element feature vectors and reduced feature vectors resulted in F-scores of 90.1%, 68.7% and 94% respectively. For the group models, F-scores were 81.3%, 65% and 67% respectively. These results demonstrate feasibility of detecting smoke inhalations with a computed feature set, but suggest high individuality of breathing patterns associated with smoking.
AB - A combination of wearable Respiratory Inductive Plethysmograph and a hand-to-mouth Proximity Sensor (PS) can be used to monitor smoking habits and smoke exposure in cigarette smokers. In our previous work, detection of smoke inhalations was achieved by using a Support Vector Machine (SVM) classifier applied to raw sensor signals with 1503-element feature vectors. This study uses empirically-defined 27 features computed from the sensor signals to reduce the length of vectors. Further reduction in the length of the feature vectors was achieved by a forward feature selection algorithm, identifying from 2 to 16 features most critical for smoke inhalations detection. For individual detection models, the 1503-element feature vectors, 27-element feature vectors and reduced feature vectors resulted in F-scores of 90.1%, 68.7% and 94% respectively. For the group models, F-scores were 81.3%, 65% and 67% respectively. These results demonstrate feasibility of detecting smoke inhalations with a computed feature set, but suggest high individuality of breathing patterns associated with smoking.
UR - https://www.scopus.com/pages/publications/84886482582
U2 - 10.1109/EMBC.2013.6610927
DO - 10.1109/EMBC.2013.6610927
M3 - Conference contribution
C2 - 24111114
AN - SCOPUS:84886482582
SN - 9781457702167
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 6031
EP - 6034
BT - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
T2 - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Y2 - 3 July 2013 through 7 July 2013
ER -