Detection of 2,4-dinitrotoluene using microcantilever sensors

  • L. A. Pinnaduwage
  • , T. Thundat
  • , J. E. Hawk
  • , D. L. Hedden
  • , P. F. Britt
  • , E. J. Houser
  • , S. Stepnowski
  • , R. A. McGill
  • , D. Bubb
  • Oak Ridge National Laboratory
  • Naval Research Laboratory
  • Seton Hall University

Research output: Contribution to journalArticlepeer-review

113 Scopus citations

Abstract

We report the gas phase detection of 2,4-dinitrotoluene (DNT) with a SXFA-[poly(1-(4-hydroxy-4-trifluoromethyl-5,5,5-trifluoro)pent-1-enyl) methylsiloxane]-polymer-coated microcantilevers. These studies show that a detection sensitivity of 300 parts-per-trillion (ppt) could be achieved within a few seconds of exposure of the sensor to the vapor stream. The response is reversible and the sensor coating has been shown to be able to withstand repeated exposure to varying levels of DNT concentrations over a year.

Original languageEnglish
Pages (from-to)223-229
Number of pages7
JournalSensors and Actuators, B: Chemical
Volume99
Issue number2-3
DOIs
StatePublished - May 1 2004

Keywords

  • Detection
  • Dinitrotoluene (DNT)
  • Microcantilever
  • Microsensor

Fingerprint

Dive into the research topics of 'Detection of 2,4-dinitrotoluene using microcantilever sensors'. Together they form a unique fingerprint.