Degradation of the bond between old and new mortar under cyclic shear loading was monitored by contact electrical resistance measurement. Degradation, causing a decrease in the bond strength, resulted in an increase in the resistance. The method allowed nondestructive monitoring of bond quality in real time during dynamic loading.
| Original language | English |
|---|---|
| Pages (from-to) | 1647-1651 |
| Number of pages | 5 |
| Journal | Cement and Concrete Research |
| Volume | 31 |
| Issue number | 11 |
| DOIs | |
| State | Published - Nov 2001 |
Keywords
- Bond strength
- Degradation
- Electrical properties
- Fatigue
- Mortar
Fingerprint
Dive into the research topics of 'Degradation of the bond between old and new mortar under cyclic shear loading, monitored by contact electrical resistance measurement'. Together they form a unique fingerprint.Cite this