Skip to main navigation Skip to search Skip to main content

Cyclic testing of pultruded fiber-reinforced plastic beam-column rigid connection

  • University of Ottawa

Research output: Contribution to journalArticlepeer-review

21 Scopus citations

Abstract

This paper reports on the following: (1) Simple experimental investigations of pultruded fiber-reinforced plastic (PFRP) material behavior and tests of simple epoxied joints to verify and enhance the reported database; (2) cyclic tests of an attempted PFRP rigid beam-column connections; and (3) preliminary observations regarding the seismic-resistance worthiness of PFRP structures. These are simple design issues that must be addressed if PFRP structural shapes are to gain broad acceptance by the design community. It is found that epoxied connections alone cannot fully exploit the high-strength potential of this material, and that delamination of components is more problematic than the inherent brittleness of the material. The cyclic flexural test of an attempted rigid beam-column con nection has revealed the particular delamination weakness of the flange-to-web core of PFRP structural shapes. The construction of rigid beam-column connections using commonly used steel details is found to be ineffective.

Original languageEnglish
Pages (from-to)2637-2652
Number of pages16
JournalJournal of Structural Engineering (United States)
Volume120
Issue number9
DOIs
StatePublished - Sep 1994

Fingerprint

Dive into the research topics of 'Cyclic testing of pultruded fiber-reinforced plastic beam-column rigid connection'. Together they form a unique fingerprint.

Cite this