Skip to main navigation Skip to search Skip to main content

Cost-effectiveness of cardiac resynchronization therapy in the MADIT-CRT trial

  • Katia Noyes
  • , Peter Veazie
  • , William Jackson Hall
  • , Hongwei Zhao
  • , April Buttaccio
  • , Kelly Thevenet-Morrison
  • , Arthur J. Moss
  • University of Rochester
  • Texas A&M University

Research output: Contribution to journalArticlepeer-review

55 Scopus citations

Abstract

Cost Effectiveness of MADIT-CRT. Background: The Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial demonstrated that cardiac resynchronization therapy (CRT) when added to the implantable cardiac defibrillator (ICD) reduces risk of heart failure or death in minimally symptomatic patients with reduced cardiac ejection fraction and wide QRS complex. Objectives: To evaluate 4-year cost-effectiveness of CRT-ICD compared to ICD alone using MADIT-CRT data. Research Design: Patients enrolled in the trial were randomized to implantation of either ICD or CRT-ICD in a 2:3 ratio, with up to 4-year follow-up period. Cost-effectiveness analyses were conducted, and sensitivity analyses by age, gender, and left bundle branch block (LBBB) conduction pattern were performed. Subjects: A total of 1,271 patients with ICD or CRT-ICD (US centers only) who reported healthcare utilization and health-related quality of life data. Measures: We used the EQ-5D (US weights) to assess patient HRQOL and translated utilization data to costs using national Medicare reimbursement rates. Results: Average 4-year healthcare expenditures in CRT-ICD patients were higher than costs of ICD patients ($62,600 vs 57,050, P = 0.015), mainly due to the device and implant-related costs. The incremental cost-effectiveness ratio of CRT-ICD compared to ICD was $58,330/quality-adjusted life years (QALY) saved. The cost effectiveness improved with longer time horizon and for the LBBB subgroup ($7,320/QALY), with no cost-effectiveness benefit being evident in the non-LBBB group. Conclusions: In minimally symptomatic patients with low ejection fraction and LBBB, CRT-ICD is cost effective within 4-year horizon when compared to ICD-only.

Original languageEnglish
Pages (from-to)66-74
Number of pages9
JournalJournal of Cardiovascular Electrophysiology
Volume24
Issue number1
DOIs
StatePublished - Jan 2013

Keywords

  • cardiac resynchronization therapy (CRT)
  • cost-effectiveness
  • health-related quality-of-life (HRQOL)
  • implantable cardioverter-defibrillator (ICD)
  • MADIT-CRT
  • survival

Fingerprint

Dive into the research topics of 'Cost-effectiveness of cardiac resynchronization therapy in the MADIT-CRT trial'. Together they form a unique fingerprint.

Cite this