Skip to main navigation Skip to search Skip to main content

Controlled compliancy of 3D printed vascular patient specific phantoms

  • Ariana B. Allman
  • , Lauren M. Shepard
  • , Alexander R. Podgorsak
  • , Ryan A. Rava
  • , Ciprian N. Ionita
  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Purpose: 3D printed (3DP) patient specific vascular phantoms provide the ability to improve device testing and to aid in the course of treatment of vascular disease, while reducing the need for in-vivo experiments. In addition to accurate vascular geometric reproducibility, such phantoms could allow simulation of certain vascular mechanical properties. We investigated various 3DP designs to allow simulation of physiological transmural pressure on phantom vasculature. Materials and Methods: A transparent compliance chamber was created using an Eden260V printer (Stratasys) with VeroClear and acrylic to accommodate 3DP patient specific vascular phantoms. The patient vascular geometries were acquired from a CT angiogram (Aquilion ONE, Canon Medical) and segmented using Vitrea workstation (Vital Images). The segmented geometry was manipulated in Autodesk Meshmixer and 3D printed using Agilus. The phantom was integrated in the compliance chamber and connected to a pump which simulated physiologic pulsatile flow waveforms. Compliance of the vessels was varied by filling the chamber with various levels of liquid and air. This setup allowed controlled expansion of the 3DP arteries, as a function of the liquid level while a programmable pump simulated the blood flow through the vascular network. The pressure within the vessels was measured for various compliancy settings while physiological flow rates were simulated through the arteries. Results: A neurovascular phantom was placed in the chamber and amount of artery expansion diameter was controlled by changing the liquid level in the compliance chamber. Artery patency and contrast flow were demonstrated using x-ray angiography. The pressures in the left and the right internal carotid artery increased from 98mmHg to 104mmHg and from 96mmHg to 102mmHg, respectively, while maintaining the same flow rates. Conclusions: 3D printed patient specific neurovascular phantoms can be manipulated through using of a compliance chamber in order to establish physiologically relevant hemodynamic conditions.

Original languageEnglish
Title of host publicationMedical Imaging 2019
Subtitle of host publicationImaging Informatics for Healthcare, Research, and Applications
EditorsPo-Hao Chen, Peter R. Bak
PublisherSPIE
ISBN (Electronic)9781510625556
DOIs
StatePublished - 2019
EventMedical Imaging 2019: Imaging Informatics for Healthcare, Research, and Applications - San Diego, United States
Duration: Feb 17 2019Feb 18 2019

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10954
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2019: Imaging Informatics for Healthcare, Research, and Applications
Country/TerritoryUnited States
CitySan Diego
Period02/17/1902/18/19

Fingerprint

Dive into the research topics of 'Controlled compliancy of 3D printed vascular patient specific phantoms'. Together they form a unique fingerprint.

Cite this