TY - GEN
T1 - Control aspects of motor neural prosthesis
T2 - 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07
AU - Popović, Dejan B.
AU - Došen, Strahinja
AU - Popović, Mirjana B.
AU - Stefanović, Filip
AU - Kojović, Jovana
PY - 2007
Y1 - 2007
N2 - A neural prosthesis (NP) has two applications: permanent assistance of function, and temporary assistance that contributes to long-term recovery of function. Here, we address control issues for a therapeutic NP which uses surface electrodes. We suggest that the effective NP for therapy needs to implement rule-based control Rule-based control relies on the triggering of preprogrammed sequences of electrical stimulation by the sensory signals. The sensory system in the therapeutic NP needs to be simple for installation, allow self-calibration, it must be robust, and sufficiently redundant in order to guaranty safe operation. The sensory signals need to generate control signals; hence, sensory fusion is needed. MEMS technology today provides sensors that fulfill the technical requirements (accelerometers, gyroscopes, force sensing resistors). Therefore, the task was to design a sensory signal processing method from the mentioned solid state sensors that would recognize phases during the gait cycle. This is necessary for the control of multi channel electrical stimulation. The sensory fusion consists of the following two phases: 1) estimation of vertical and horizontal components of the ground reaction force, center of pressure, and joint angles from the solid-state sensors, and 2) fusion of the estimated signals into a sequence of command signals. The first phase was realized by the use of artificial neural networks and adaptive neuro-fuzzy inference systems, while the second by the use of inductive learning described in our earlier work [1].
AB - A neural prosthesis (NP) has two applications: permanent assistance of function, and temporary assistance that contributes to long-term recovery of function. Here, we address control issues for a therapeutic NP which uses surface electrodes. We suggest that the effective NP for therapy needs to implement rule-based control Rule-based control relies on the triggering of preprogrammed sequences of electrical stimulation by the sensory signals. The sensory system in the therapeutic NP needs to be simple for installation, allow self-calibration, it must be robust, and sufficiently redundant in order to guaranty safe operation. The sensory signals need to generate control signals; hence, sensory fusion is needed. MEMS technology today provides sensors that fulfill the technical requirements (accelerometers, gyroscopes, force sensing resistors). Therefore, the task was to design a sensory signal processing method from the mentioned solid state sensors that would recognize phases during the gait cycle. This is necessary for the control of multi channel electrical stimulation. The sensory fusion consists of the following two phases: 1) estimation of vertical and horizontal components of the ground reaction force, center of pressure, and joint angles from the solid-state sensors, and 2) fusion of the estimated signals into a sequence of command signals. The first phase was realized by the use of artificial neural networks and adaptive neuro-fuzzy inference systems, while the second by the use of inductive learning described in our earlier work [1].
UR - https://www.scopus.com/pages/publications/57649149754
U2 - 10.1109/IEMBS.2007.4353303
DO - 10.1109/IEMBS.2007.4353303
M3 - Conference contribution
C2 - 18002969
AN - SCOPUS:57649149754
SN - 1424407885
SN - 9781424407880
T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
SP - 4361
EP - 4363
BT - 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07
Y2 - 23 August 2007 through 26 August 2007
ER -