Skip to main navigation Skip to search Skip to main content

Component analysis of a new Solid State x-ray image intensifier (SSXII) using photon transfer and instrumentation noise equivalent exposure (INEE) measurements

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

14 Scopus citations

Abstract

The SSXII is a novel x-ray imager designed to improve upon the performance limitations of conventional dynamic radiographic/fluoroscopic imagers related to resolution, charge-trapping, frame-rate, and instrumentation-noise. The SSXII consists of a CsI:Tl phosphor coupled via a fiber-optic taper (FOT) to an electron-multiplying CCD (EMCCD). To facilitate investigational studies, initial designs enable interchangeability of such imaging components. Measurements of various component and configuration characteristics enable an optimization analysis with respect to overall detector performance. Photon transfer was used to characterize the EMCCD performance including ADC sensitivity, read-noise, full-well capacity and quantum efficiency. X-ray sensitivity was measured using RQA x-ray spectra. Imaging components were analyzed in terms of their MTF and transmission efficiency. The EMCCD was measured to have a very low effective read-noise of less than 1 electron rms at modest EMCCD gains, which is more than two orders-ofmagnitude less than flat panel (FPD) and CMOS-based detectors. The variable signal amplification from 1 to 2000 times enables selectable sensitivities ranging from 8.5 (168) to over 15k (300k) electrons per incident x-ray photon with (without) a 4:1 FOT; these sensitivities could be readily increased with further component optimization. MTF and DQE measurements indicate the SSXII performance is comparable to current state-of-the-art detectors at low spatial frequencies and far exceeds them at higher spatial frequencies. The instrumentation noise equivalent exposure (INEE) was measured to be less than 0.3 μR out to 10 cycles/mm, which is substantially better than FPDs. Component analysis suggests that these improvements can be substantially increased with further detector optimization.

Original languageEnglish
Title of host publicationMedical Imaging 2009
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2009
EventMedical Imaging 2009: Physics of Medical Imaging - Lake Buena Vista, FL, United States
Duration: Feb 9 2009Feb 12 2009

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume7258
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2009: Physics of Medical Imaging
Country/TerritoryUnited States
CityLake Buena Vista, FL
Period02/9/0902/12/09

Keywords

  • Detectors
  • DQE
  • EMCCD
  • High-resolution
  • INEE
  • MTF
  • Solid-state x-ray image intensifier
  • SSXII

Fingerprint

Dive into the research topics of 'Component analysis of a new Solid State x-ray image intensifier (SSXII) using photon transfer and instrumentation noise equivalent exposure (INEE) measurements'. Together they form a unique fingerprint.