Skip to main navigation Skip to search Skip to main content

Comparison of Susceptibility Weighted Imaging and TOF-Angiography for the Detection of Thrombi in Acute Stroke

  • Alexander Radbruch
  • , Johanna Mucke
  • , Ferdinand Schweser
  • , Andreas Deistung
  • , Peter Alexander Ringleb
  • , Christian Herbert Ziener
  • , Matthias Roethke
  • , Heinz Peter Schlemmer
  • , Sabine Heiland
  • , Jürgen R. Reichenbach
  • , Martin Bendszus
  • , Stefan Rohde
  • Heidelberg University 
  • German Cancer Research Center
  • Friedrich Schiller University Jena

Research output: Contribution to journalArticlepeer-review

57 Scopus citations

Abstract

Background and Purpose:Time-of-flight (TOF) angiography detects embolic occlusion of arteries in patients with acute ischemic stroke due to the absence of blood flow in the occluded vessel. In contrast, susceptibility weighted imaging (SWI) directly enables intravascular clot visualization due to hypointense susceptibility vessel signs (SVS) in the occluded vessel. The aim of this study was to compare the diagnostic accuracy of both methods to determine vessel occlusion in patients with acute stroke.Methods:94 patients were included who presented with clinical symptoms for acute stroke and displayed a delay on the time-to-peak perfusion map in the territory of the anterior (ACA), middle (M1, M1/M2, M2/M3) or posterior (PCA) cerebral artery. The frequency of SVS on SWI and vessel occlusion or stenosis on TOF-angiography was compared using the McNemar-Test.Results:87 of 94 patients displayed a clearly definable SVS on SWI. In 72 patients the SVS was associated with occlusion or stenosis on TOF-angiography. Fifteen patients exclusively displayed SVS on SWI (14 M2/M3, 1 M1), whereas no patient revealed exclusively occlusion or stenosis on TOF-angiography. Sensitivity for detection of embolic occlusion within major vessel segments (M1, M1/M2, ACA, and PCA) did not show any significant difference between both techniques (97% for SWI versus 96% for TOF-angiography) while the sensitivity for detection of embolic occlusion within M2/M3 was significantly different (84% for SWI versus 39% for TOF-angiography, p<0.00012).Conclusions:SWI and TOF-angiography provide similar sensitivity for central thrombi while SWI is superior for the detection of peripheral thrombi in small arterial vessel segments.

Original languageEnglish
Article numbere63459
JournalPLOS ONE
Volume8
Issue number5
DOIs
StatePublished - May 23 2013

Fingerprint

Dive into the research topics of 'Comparison of Susceptibility Weighted Imaging and TOF-Angiography for the Detection of Thrombi in Acute Stroke'. Together they form a unique fingerprint.

Cite this