Skip to main navigation Skip to search Skip to main content

Comparison of pulsatile flow dynamics before and after endovascular intervention in 3D-printed patient-specific internal carotid artery aneurysm models using 1000 fps photon-counting detectors for Simultaneous Biplane High Speed Angiography (SB-HSA)

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

4 Scopus citations

Abstract

A significant challenge regarding the treatment of aneurysms is the variability in morphology and analysis of abnormal flow. With conventional DSA, low frame rates limit the flow information available to clinicians at the time of the vascular intervention. With 1000 fps High-Speed Angiography (HSA), high frame rates enable flow details to be better resolved for endovascular interventional guidance. The purpose of this work is to demonstrate how 1000 fps biplane-HSA can be used to differentiate flow features, such as vortex formation and endoleaks, amongst patient-specific internal carotid artery aneurysm phantoms pre- and post-endovascular intervention using an in-vitro flow setup. The aneurysm phantoms were attached to a flow loop configured to a carotid waveform, with automated injections of contrast media. Simultaneous Biplane High-Speed Angiographic (SB- HSA) acquisitions were obtained at 1000 fps using two photon-counting detectors with the respective aneurysm and inflow/ outflow vasculature in the FOV. After x-rays were turned on, the detector acquisitions occurred simultaneously, during which iodine contrast was injected at a continuous rate. A pipeline stent was then deployed to divert flow from the aneurysm, and image sequences were once again acquired using the same parameters. Optical Flow, an algorithm that calculates velocity based on spatial-temporal intensity changes between pixels, was used to derive velocity distributions from HSA image sequences. Both the image sequences and velocity distributions indicate detailed changes in flow features amongst the aneurysms before and after deployment of the interventional device. SBHSA can provide detailed flow analysis, including streamline and velocity changes, which may be beneficial for interventional guidance.

Original languageEnglish
Title of host publicationMedical Imaging 2023
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
EditorsBarjor S. Gimi, Andrzej Krol
PublisherSPIE
ISBN (Electronic)9781510660410
DOIs
StatePublished - 2023
EventMedical Imaging 2023: Biomedical Applications in Molecular, Structural, and Functional Imaging - San Diego, United States
Duration: Feb 19 2023Feb 22 2023

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume12468
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2023: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CitySan Diego
Period02/19/2302/22/23

Keywords

  • 1000 fps
  • High-speed angiography (HSA)
  • aneurysm
  • biplane
  • endovascular intervention
  • hemodynamics
  • photon-counting detector (PCD)
  • pipeline stent

Fingerprint

Dive into the research topics of 'Comparison of pulsatile flow dynamics before and after endovascular intervention in 3D-printed patient-specific internal carotid artery aneurysm models using 1000 fps photon-counting detectors for Simultaneous Biplane High Speed Angiography (SB-HSA)'. Together they form a unique fingerprint.

Cite this