Skip to main navigation Skip to search Skip to main content

Co-registration of infarct core location with angiography during mechanical thrombectomy procedures for treatment progression monitoring

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Purpose: The standard workflow for patients affected by acute ischemic stroke (AIS) due to large vessel occlusions (LVO) includes diagnosis using CT-perfusion (CTP) followed by image-guided mechanical thrombectomy (MT). The CTP is used to establish the ischemic tissue location and size; however, during the MT procedure this information is not currently available in the angiographic suites. We developed a method to co-register the infarct location with the angiograms in order to monitor the reperfusion of the tissue affected by the ischemia. Materials and Methods: We used the complex tortuosity of the cerebral vasculature as its own fiducial system to co-register the CTP data with the angiographic sequences acquired during MT. A carotid segment was used to create a complete set of projections for different 3D transformations which included: rotation and translation. The 3D transformation which minimized the difference between the projected data and the angiogram section containing the carotid was selected and applied to co-register the infarct core from CTP onto the angiographic sequences. Angiographic parametric imaging was performed and average mean transit time (MTT), time to peak (TTP), cerebral blood volume (CBV) and cerebral blood flow (CBF) measurements were monitored in the infarct core pre-and post-thrombectomy. We then tested co-registration accuracy using phantoms as a ground truth to evaluate registration accuracy. Results: Using the proposed method we were able to monitor flow changes in the infarct core during MT. Changes of parameters between 50% and 100% were observed following the MT. Co-registration performance analysis yielded a 0.69 average DICE coefficient score for the entire image and a 0.82 average DICE coefficient for the Circle of Willis. Conclusions: CTP data can be used to improve guidance during MT for patients with AIS using infarct core co-registration with angiographic sequences.

Original languageEnglish
Title of host publicationMedical Imaging 2020
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
EditorsAndrzej Krol, Barjor S. Gimi
PublisherSPIE
ISBN (Electronic)9781510634015
DOIs
StatePublished - 2020
EventMedical Imaging 2020: Biomedical Applications in Molecular, Structural, and Functional Imaging - Houston, United States
Duration: Feb 18 2020Feb 20 2020

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume11317
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2020: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CityHouston
Period02/18/2002/20/20

Fingerprint

Dive into the research topics of 'Co-registration of infarct core location with angiography during mechanical thrombectomy procedures for treatment progression monitoring'. Together they form a unique fingerprint.

Cite this