Abstract
Direct displacement-based seismic design has been recently proposed for the seismic design of non-structural building elements. This paper deals with the development of damping models, relating equivalent viscous damping ratio to drift amplitude, for suspended piping trapeze restraint installations for direct displacement-based seismic design. The damping models are developed using reversed cyclic test data available in the literature. First, damping models are proposed using Jacobsen’s equal area approach. The damping models developed using Jacobsen’s approach are then assessed and calibrated using nonlinear time history analyses of single degree-of-freedom archetypes representing suspended piping trapeze restraint installations in buildings.
| Original language | English |
|---|---|
| Pages (from-to) | 8063-8091 |
| Number of pages | 29 |
| Journal | Journal of Earthquake Engineering |
| Volume | 26 |
| Issue number | 15 |
| DOIs | |
| State | Published - 2022 |
Keywords
- direct displacement-based seismic design
- Equivalent viscous damping
- non-structural elements
- nonstructural components
- suspended piping trapeze restraint installations
Fingerprint
Dive into the research topics of 'Calibrated Equivalent Viscous Damping for Direct Displacement-Based Seismic Design of Suspended Piping Trapeze Restraint Installations'. Together they form a unique fingerprint.Cite this