The objective of this paper is to provide a brief overview of damage as observed immediately following the earthquake. Detailed studies of structural seismic performance, conducted in the time elapsed since August 1999, are not the subject of this paper, but rather the object of other papers presented in this Special Issue of the Journal. Damage to reinforced concrete, masonry, and steel structures, is described. The mode the failure presented include: foundation failures; soft stories; strong beams and weak columns; lack of column confinement and poor detailing practice; buckling and fractures of steel members; and non-structural damage. Some general lessons learned from this earthquake are also formulated.
| Original language | English |
|---|---|
| Pages (from-to) | 357-377 |
| Number of pages | 21 |
| Journal | Journal of Seismology |
| Volume | 6 |
| Issue number | 3 |
| DOIs | |
| State | Published - Jul 2002 |
Keywords
- Buildings
- Code
- Concrete
- Damage
- Design
- Detailing
- Earthquake
- Masonry
- Steel
Fingerprint
Dive into the research topics of 'Building damage from the Marmara, Turkey earthquake of August 17, 1999'. Together they form a unique fingerprint.Cite this