Skip to main navigation Skip to search Skip to main content

Asymmetric vascular stent: Feasibility study of a new low-porosity patch-containing stent

  • SUNY Buffalo
  • Women and Children's Hospital of Buffalo

Research output: Contribution to journalArticlepeer-review

33 Scopus citations

Abstract

BACKGROUND AND PURPOSE-Intracranial aneurysm (IA) treatment through hemodynamic modification with novel stent designs is a burgeoning area of research. We present a feasibility study for a new low-porosity patch-containing stent designed to treat intracranial aneurysms. The device is deployed so the patch covers the aneurysm neck ensuring strong flow diversion away from the aneurysm while keeping a low probability of occlusion of perforating vessels. METHODS-We created 17 side-wall aneurysms in 6 dogs, 2 per carotid artery if animal size permitted. Twelve proximal aneurysms were treated with AVSs: 5 distal aneurysms were untreated, serving as controls against self-thrombosis; 7 treated aneurysms were fully-covered; and 5 were partially-covered. After 4 weeks, a final angiogram was performed and aneurysms were explanted. Angiograms acquired pre- and posttreatment and at 4-week follow-up were analyzed quantitatively using normalized time-density curves (NTDC). Cone-beam micro-CT and histological specimen analysis were then performed. RESULTS-Posttreatment, NTDC average peaks dropped to 45% of initial values for the partially-covered aneurysms and 78% for the fully-covered aneurysms. Cone-beam micro-CT imaging performed at 4 weeks posttreatment showed partial thrombosis in 4 of 5 partially-covered aneurysms and complete thrombosis in all fully-covered aneurysms. Histology revealed neointimal coverage of all asymmetrical patch regions and thrombus formation in both fully- and partially-covered aneurysms. Four-week follow-up was not done for 1 animal (2 controls, 2 treated) that expired because of groin hemorrhage and for another animal (1 aneurysm) with an occluded carotid. CONCLUSIONS-We demonstrate aneurysmal blood flow diversion using a new low-porosity patch-containing asymmetrical vascular stent in a canine side-wall aneurysm model. Overall results are encouraging and support continued AVS development.

Original languageEnglish
Pages (from-to)2105-2113
Number of pages9
JournalStroke
Volume39
Issue number7
DOIs
StatePublished - Jul 1 2008

Keywords

  • Canine model
  • Neurysm
  • Stent
  • Time-density curve

Fingerprint

Dive into the research topics of 'Asymmetric vascular stent: Feasibility study of a new low-porosity patch-containing stent'. Together they form a unique fingerprint.

Cite this