The Bolu viaduct is a 2.3-km-long seismically isolated structure that was nearly complete when it was struck by the 1999 Duzce earthquake in Turkey. It suffered complete failure of the seismic isolation system and narrowly avoided total collapse due to excessive superstructure movement. This paper presents an evaluation of the design of the viaduct's seismic isolation system and an assessment of its performance in the Duzce earthquake. Evaluation of the seismic isolation system's design has revealed that it did not meet the requirements of the AASHTO Guide Specifications for Seismic Isolation Design. Analysis of the viaduct with motions scaled in accordance with the AASHTO Guide Specifications resulted in a displacement demand of 820 mm, which is far more than the 210 mm displacement capacity of the existing isolation system. Analysis of the viaduct for a simulated near-fault motion with characteristics consistent with the site conditions resulted in an isolation system displacement demand of 1,400 mm. This indicates that, even if the isolation system had been designed in compliance with the AASHTO, it would have still suffered damage in the earthquake.

Original languageEnglish
Pages (from-to)182-190
Number of pages9
JournalJournal of Bridge Engineering
Volume8
Issue number4
DOIs
StatePublished - Jul 2003

Keywords

  • Bridges, viaduct
  • Earthquake damage
  • Seismic isolation
  • Turkey

Fingerprint

Dive into the research topics of 'Assessment of performance of seismic isolation system of Bolu Viaduct'. Together they form a unique fingerprint.

Cite this