Skip to main navigation Skip to search Skip to main content

Anti-scatter grid artifact elimination for high-resolution x-ray imaging detectors without a prior scatter distribution profile

  • SUNY Buffalo

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Scopus citations

Abstract

Using anti-scatter grids with high-resolution imaging detectors could result in grid-line artifacts, with increasing severity as detector resolution improves. Grid-line mask subtraction can result in residual artifacts that are due to residual scatter penetrating the grid and not subtracted. By subtracting this residual scatter, the grid artifacts can be minimized. In the previous works, an initial residual-scatter estimate was derived by placing lead markers on a test object; however, any change in the object geometry requires a new scatter estimate. Such a method is impractical to implement during a clinical procedure. In this work, we present a new method to derive the initial scatter estimate to eliminate grid-line artifacts during a procedure. A standard stationary Smit-Roentgen x-ray grid (line density - 70 lines/cm, grid ratio - 13:1) was used with a high-resolution CMOS detector (Dexela Model 1207, pixel size - 75 μm) to image an anthropomorphic head phantom. The initial scatter estimate was derived from the image itself and the grid artifacts were eliminated using recursive correction estimation; this result was compared to that with the estimate derived from placing lead markers on the phantom. In both cases, the contrast-to-noise ratio (CNR) was improved compared to the original image with grid artifacts. Percentage differences in CNR's for three regions between the images corrected with the two estimates were less than 5%. With the new method no a priori scatter distribution profiles are needed, eliminating the need to have libraries of pre-calculated scatter profiles and making the implementation more clinically practical.

Original languageEnglish
Title of host publicationMedical Imaging 2018
Subtitle of host publicationPhysics of Medical Imaging
EditorsTaly Gilat Schmidt, Guang-Hong Chen, Joseph Y. Lo
PublisherSPIE
ISBN (Electronic)9781510616356
DOIs
StatePublished - 2018
EventMedical Imaging 2018: Physics of Medical Imaging - Houston, United States
Duration: Feb 12 2018Feb 15 2018

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10573
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2018: Physics of Medical Imaging
Country/TerritoryUnited States
CityHouston
Period02/12/1802/15/18

Fingerprint

Dive into the research topics of 'Anti-scatter grid artifact elimination for high-resolution x-ray imaging detectors without a prior scatter distribution profile'. Together they form a unique fingerprint.

Cite this