Skip to main navigation Skip to search Skip to main content

An MLEM Reconstruction Method with Mixed Events Based on a Cascade Gamma Emission Imager System

  • Xiao Liu
  • , Hui Liu
  • , Li Cheng
  • , Zheng Gu
  • , Rutao Yao
  • , Yaqiang Liu
  • Tsinghua University
  • Shenzhen Bay Laboratory

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

Many medical radionuclides can emit cascade photons sequentially, yet commercial imaging equipment like PET or SPECT don't make use of this information. We have developed a cascade gamma emission imager system to detect the cascade photons in coincidence for those radionuclide imaging. In previous study, reasonable reconstruction images could be obtained using coincidence event based MLEM (CE-MLEM) but with a low signal-to-noise ratio (SNR), caused by the poor sensitivity of the coincidence event. In this work, we proposed an MLEM with mixed events (ME-MLEM) reconstruction method based on the coincidence events incorporated with the simultaneously detected single photons to improve the SNR while maintaining the spatial resolution. A myocardial phantom filled with 1 mCi 177Lu3+ solution was scanned for 1 hour on our prototype setup. 1.36×104 coincidence events and 8.27×107 single photons were acquired under a 25.6 ns CTW and 10.8%/14.6% @ 208/113 KeV energy window. CE-MLEM, single photon based MLEM (SP-MLEM), and ME-MLEM with a 0.001 weighting factor between coincidence events and single photons were then used for the image reconstruction. The results showed the potential for ME-MLEM to improve the image SNR while keeping the same spatial resolution as CE-MLEM. Our results demonstrated that our system's image quality could be improved when combined coincidence events and single photons together.

Original languageEnglish
Title of host publication2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781728176932
DOIs
StatePublished - 2020
Event2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020 - Boston, United States
Duration: Oct 31 2020Nov 7 2020

Publication series

Name2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020

Conference

Conference2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020
Country/TerritoryUnited States
CityBoston
Period10/31/2011/7/20

Keywords

  • Cascade gamma imaging
  • Dual photon emission computed tomography system
  • MLEM reconstruction with mixed events

Fingerprint

Dive into the research topics of 'An MLEM Reconstruction Method with Mixed Events Based on a Cascade Gamma Emission Imager System'. Together they form a unique fingerprint.

Cite this