TY - GEN
T1 - A Spatiotemporal Illumination Model for 3d Image Fusion in Optical Coherence Tomography
AU - Ploner, Stefan
AU - Won, Jungeun
AU - Schottenhamml, Julia
AU - Girgis, Jessica
AU - Lam, Kenneth
AU - Waheed, Nadia
AU - Fujimoto, James
AU - Maier, Andreas
N1 - Publisher Copyright:
© 2023 IEEE.
PY - 2023
Y1 - 2023
N2 - Optical coherence tomography (OCT) is a non-invasive, micrometer-scale imaging modality that has become a clinical standard in ophthalmology. By raster-scanning the retina, sequential cross-sectional image slices are acquired to generate volumetric data. In-vivo imaging suffers from discontinuities between slices that show up as motion and illumination artifacts. We present a new illumination model that exploits continuity in orthogonally raster-scanned volume data. Our novel spatiotemporal parametrization adheres to illumination continuity both temporally, along the imaged slices, as well as spatially, in the transverse directions. Yet, our formulation does not make inter-slice assumptions, which could have discontinuities. This is the first optimization of a 3D inverse model in an image reconstruction context in OCT. Evaluation in 68 volumes from eyes with pathology showed reduction of illumination artifacts in 88% of the data, and only 6% showed moderate residual illumination artifacts. The method enables the use of forward-warped motion corrected data, which is more accurate, and enables supersampling and advanced 3D image reconstruction in OCT.
AB - Optical coherence tomography (OCT) is a non-invasive, micrometer-scale imaging modality that has become a clinical standard in ophthalmology. By raster-scanning the retina, sequential cross-sectional image slices are acquired to generate volumetric data. In-vivo imaging suffers from discontinuities between slices that show up as motion and illumination artifacts. We present a new illumination model that exploits continuity in orthogonally raster-scanned volume data. Our novel spatiotemporal parametrization adheres to illumination continuity both temporally, along the imaged slices, as well as spatially, in the transverse directions. Yet, our formulation does not make inter-slice assumptions, which could have discontinuities. This is the first optimization of a 3D inverse model in an image reconstruction context in OCT. Evaluation in 68 volumes from eyes with pathology showed reduction of illumination artifacts in 88% of the data, and only 6% showed moderate residual illumination artifacts. The method enables the use of forward-warped motion corrected data, which is more accurate, and enables supersampling and advanced 3D image reconstruction in OCT.
KW - illumination correction
KW - image reconstruction
KW - inverse model
KW - ophthalmology
KW - Optical coherence tomography
UR - https://www.scopus.com/pages/publications/85172125552
U2 - 10.1109/ISBI53787.2023.10230526
DO - 10.1109/ISBI53787.2023.10230526
M3 - Conference contribution
AN - SCOPUS:85172125552
T3 - Proceedings - International Symposium on Biomedical Imaging
BT - 2023 IEEE International Symposium on Biomedical Imaging, ISBI 2023
PB - IEEE Computer Society
T2 - 20th IEEE International Symposium on Biomedical Imaging, ISBI 2023
Y2 - 18 April 2023 through 21 April 2023