Skip to main navigation Skip to search Skip to main content

A simplified method of pre-emptive perigraft aortic sac embolization to prevent type II endoleak using the Excluder endograft

  • SUNY Buffalo
  • Department of Veterans Affairs

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Pre-emptive, nonselective perigraft embolization of abdominal aortic aneurysm sac to reduce the risk of type II endoleak has been previously reported with a percutaneous technique using contralateral access with resheathing for coiling. The approach has been modified to simplify the procedure and to eliminate unnecessary sheath exchanges.

Original languageEnglish
Pages (from-to)509-511
Number of pages3
JournalJournal of Vascular Surgery Cases
Volume5
Issue number4
DOIs
StatePublished - Dec 2019

Keywords

  • Embolization
  • Endoleak
  • Endovascular aneurysm repair

Fingerprint

Dive into the research topics of 'A simplified method of pre-emptive perigraft aortic sac embolization to prevent type II endoleak using the Excluder endograft'. Together they form a unique fingerprint.