Skip to main navigation Skip to search Skip to main content

A propensity score-matched comparative study of balloon guide catheters versus conventional guide catheters for concurrent mechanical thrombectomy with carotid stenting in tandem strokes: Comparison of first pass effect, symptomatic intracranial hemorrhage, and 90-day functional outcomes

  • SUNY Buffalo
  • Women and Children's Hospital of Buffalo

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Background Extensive clot burden in tandem strokes accounts for poor mechanical thrombectomy (MT) outcomes. Several studies have shown the benefit of balloon guide catheters (BGCs) in MT and carotid artery stenting. Objective In view of this potential benefit, to investigate the safety and effectiveness of proximal flow arrest using a BGC during concurrent MT and carotid revascularization for tandem stroke treatment in a comparative, propensity score-matched (PSM) study. Methods Patients with a tandem stroke identified from our endovascular database were dichotomized into groups treated with BGCs versus conventional guide catheters. One-to-one PSM adjustment for baseline demographics and treatment selection bias using nearest-neighbor matching was performed. Patient demographics, presentation characteristics, and procedural details were recorded. Outcomes assessed were final modified Thrombolysis in Cerebral Infarction (mTICI) grade, periprocedural symptomatic intracranial hemorrhage (sICH) rate, in-hospital mortality, and 90-day modified Rankin Scale (mRS) score. Mann-Whitney U test and multivariate logistic regression were performed to compare procedural parameters and clinical outcomes. Results Concurrent carotid revascularization (stenting with/without angioplasty) and MT was performed in 125 cases (BGC: 85; no BGC: 40). After PSM (40 patients/group), the BGC group had a significantly shorter procedure duration (77.9 vs 61.5 min; OR=0.996; P=0.006), lower discharge National Institutes of Health Stroke Scale score (8.0 vs 11.0; OR=0.987; P=0.042), and higher odds of 90-day mRS 0-2 score (52.3% vs 27.5%; OR=0.34; P=0.040). On multivariate regression, the BGC group had a significantly higher first pass effect rate (mTICI 2b or 3)(OR=1.115, 95% CI 1.015 to 1.432; P=0.013) and lower periprocedural sICH rate (OR=0.615, 95% CI 0.406 to 0.932; P=0.025). No difference in in-hospital mortality was observed (OR=1.591, 95% CI 0.976 to 2.593; P=0.067). Conclusion BGCs used for concurrent MT-carotid revascularization with flow arrest were safe and resulted in superior clinical and angiographic outcomes in patients with a tandem stroke.

Original languageEnglish
Pages (from-to)124-130
Number of pages7
JournalJournal of NeuroInterventional Surgery
Volume16
Issue number2
DOIs
StatePublished - Apr 19 2023

Keywords

  • balloon
  • catheter
  • stent
  • stroke
  • thrombectomy

Fingerprint

Dive into the research topics of 'A propensity score-matched comparative study of balloon guide catheters versus conventional guide catheters for concurrent mechanical thrombectomy with carotid stenting in tandem strokes: Comparison of first pass effect, symptomatic intracranial hemorrhage, and 90-day functional outcomes'. Together they form a unique fingerprint.

Cite this