Abstract

BACKGROUND AND PURPOSE: The ROI-dose-reduced intervention technique represents an extension of ROI fluoroscopy combining x-ray entrance skin dose reduction with spatially different recursive temporal filtering to reduce excessive image noise in the dosereduced periphery in real-time. The aim of our study was to compare the image quality of simulated neurointerventions with regular and reduced radiation doses using a standard flat panel detector system. MATERIALS AND METHODS: Ten 3D-printed intracranial aneurysm models were generated on the basis of a single patient vasculature derived from intracranial DSA and CTA. The incident dose to each model was reduced using a 0.7-mm-thick copper attenuator with a circular ROI hole (10-mm diameter) in the middle mounted inside the Infinix C-arm. Each model was treated twice with a primary coiling intervention using ROI-dose-reduced intervention and regular-dose intervention protocols. Eighty images acquired at various intervention stages were shown twice to 2 neurointervention a lists who independently scored imaging qualities (visibility of aneurysm-parent vessel morphology, associated vessels, and/or devices used). Dose-reduction measurements were performed using an ionization chamber. RESULTS: A total integral dose reduction of 62% per frame was achieved. The mean scores for regular-dose intervention and ROI dose-reduced intervention images did not differ significantly, suggesting similar image quality. Overall intrarater agreement for all scored criteria was substantial (Kendall T = 0.62887; P <.001). Overall interrater agreement for all criteria was fair (K = 0.2816; 95% CI, 0.2060-0.3571). CONCLUSIONS: Substantial dose reduction (62%) with a live peripheral image was achieved without compromising feature visibility during neuroendovascular interventions.

Original languageEnglish
Pages (from-to)734-741
Number of pages8
JournalAmerican Journal of Neuroradiology
Volume39
Issue number4
DOIs
StatePublished - Apr 1 2018

Fingerprint

Dive into the research topics of 'A patient dose-reduction technique for neuroendovascular image-guided interventions: Image-quality comparison study'. Together they form a unique fingerprint.

Cite this