Skip to main navigation Skip to search Skip to main content

A passive design strategy for a horizontal ground source heat pump pipe operation optimization with a non-homogeneous soil profile

  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

25 Scopus citations

Abstract

The effectiveness of a non-homogeneous soil profile for horizontal ground source heat pumps (GSHPs), defined as natural backfill with an intermediate layer of material having different thermal characteristics, is investigated. Steps toward development of a comprehensive model to consider the effects of the non-homogeneous layer are described. The developed model is utilized successfully in conjunction with a genetic algorithm (GA) search method to obtain the optimized operational parameters for a GSHP in three different climate conditions. A properly sized and engineered non-homogeneous soil profile demonstrated the potential to increase the energy extraction/dissipation rates from/to the ground to a significant level. The potential benefit of a recycled product, Tire Derived Aggregate (TDA), as an insulating non-homogeneous layer is assessed. TDA is demonstrated to be more effective in the cold climate (Buffalo) by increasing the energy extraction rates from the ground approximately 15% annually. TDA's effectiveness is less pronounced in a relatively moderate climate (Dallas) by increasing the energy extraction rates from the ground about 4% annually. For the cooling only scenario (Miami), a high conductive intermediate layer of saturated sand exhibited greater potential to increase the energy dissipation to the ground.

Original languageEnglish
Pages (from-to)39-50
Number of pages12
JournalEnergy and Buildings
Volume61
DOIs
StatePublished - 2013

Keywords

  • Control
  • Energy efficiency
  • Genetic algorithm
  • Horizontal ground source heat pump
  • Non-homogeneous soil
  • Optimization
  • Tire Derived Aggregate

Fingerprint

Dive into the research topics of 'A passive design strategy for a horizontal ground source heat pump pipe operation optimization with a non-homogeneous soil profile'. Together they form a unique fingerprint.