Abstract

We report a new sensor concept based on an ion-selective SAM modified microcantilever which can detect caesium ion concentrations in situ in the range 10-11-10-7 M and shows potential for use in developing a new family of real time in situ metal ion sensors with high sensitivity/selectivity and low cost, for chemical and biological applications.