A Novel Junctional Tether Weave Technique for Adult Spinal Deformity: 2-Dimensional Operative Video

  • Thomas J. Buell
  • , Jeffrey P. Mullin
  • , James H. Nguyen
  • , Davis G. Taylor
  • , Juanita Garces
  • , Marcus D. Mazur
  • , Avery L. Buchholz
  • , Mark E. Shaffrey
  • , Chun Po Yen
  • , Christopher I. Shaffrey
  • , Justin S. Smith
  • University of Virginia
  • Medical University of South Carolina

Research output: Contribution to journalArticlepeer-review

19 Scopus citations

Abstract

Proximal junctional kyphosis (PJK) is a common problem after multilevel spine instrumentation for adult spinal deformity. Various anti-PJK techniques such as junctional tethers for ligamentous augmentation have been proposed. We present an operative video demonstrating technical nuances of junctional tether "weave" application. A 70-yr-old male with prior L2-S1 instrumented fusion presented with worsening back pain and posture. Imaging demonstrated pathological loss of lumbar lordosis (flat back deformity), proximal junctional failure, and pseudarthrosis. The patient had severe global and segmental sagittal malalignment, with sagittal vertical axis (SVA, C7-plumbline) measuring 22.3 cm, pelvic incidence (PI) 55°, lumbar lordosis (LL) 8° in kyphosis, pelvic tilt (PT) 30°, and thoracic kyphosis (TK) 6°. The patient gave informed consent for surgery and use of imaging for medical publication. Briefly, surgery first involved re-instrumentation with bilateral pedicle screws from T10 to S1. After right-sided iliac screw fixation (left-sided iliac screw fixation was not performed due to extensive prior iliac crest bone graft harvesting), we then completed a L2-3 Smith-Petersen osteotomy, extended L4 pedicle subtraction osteotomy, and L3-4 interbody arthrodesis with a 12° lordotic cage (9 × 14 × 40 mm). Cobalt Chromium rods were placed spanning the instrumentation bilaterally, and accessory supplemental rods spanning the PSO were attached. An anti-PJK junctional tether "weave" was then implemented using 4.5 mm polyethylene tape (Mersilene tape [Ethicon, Somerville, New Jersey]). Postoperative imaging demonstrated improved alignment (SVA 2.8 cm, PI 55°, LL 53°, PT 25°, TK 45°) and no significant neurological complications occurred during convalescence or at 6 mo postop.

Original languageEnglish
Pages (from-to)E45-E46
JournalOperative Neurosurgery
Volume16
Issue number2
DOIs
StatePublished - Feb 1 2019

Keywords

  • Deformity
  • Proximal junctional failure
  • Proximal junctional kyphosis
  • Scoliosis
  • Spine surgery
  • Surgical technique
  • Tether

Fingerprint

Dive into the research topics of 'A Novel Junctional Tether Weave Technique for Adult Spinal Deformity: 2-Dimensional Operative Video'. Together they form a unique fingerprint.

Cite this