Skip to main navigation Skip to search Skip to main content

A First-in-Human Evaluation of a Novel Mesh-Covered Stent for Treatment of Carotid Stenosis in Patients at High Risk for Endarterectomy: 30-Day Results of the SCAFFOLD Trial

  • Peter A. Schneider
  • , Elad Levy
  • , J. Michael Bacharach
  • , D. Christopher Metzger
  • , Bryan Randall
  • , Andrew Garcia
  • , Adnan Siddiqui
  • , Claudio Schonholz
  • , William Gray
  • Kaiser Permanente
  • North Central Heart Institute
  • Wellmont CVA Heart and Vascular Institute
  • W. L. Gore & Associates
  • Medical University of South Carolina
  • Main Line Health

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Objectives: The primary purpose of this study was the composite of major adverse events through 30 days post-index procedure or ipsilateral stroke from 30 days to 1 year (365 days). Presented here is the composite of death, stroke, and myocardial infarction (MI) through 30 days. Background: Rates of minor stroke have been higher with carotid artery stenting (CAS) compared with carotid endarterectomy (CEA). The study hypothesized that a stent with mesh covering may improve plaque stabilization during CAS, reduce plaque protrusion, and lead to reduced stroke rates. Methods: The SCAFFOLD trial, a prospective, multicenter, single-arm clinical trial evaluating the GORE carotid stent (GCS), enrolled patients at increased risk for adverse events from CEA with severe carotid artery stenosis (defined as symptomatic ≥50% or asymptomatic ≥80%). The SCAFFOLD trial screening committee was implemented to determine adherence to the study protocol. Patients were evaluated for the primary endpoint, the composite of death, stroke, and MI through 30 days. Results: A total of 312 patients were enrolled, treated, and reviewed by the SCAFFOLD trial screening committee, of which 265 were included in the primary analysis population. The 30-day rate of death, stroke, or MI was 3.0% (95% confidence interval: 1.3% to 5.9%) and the stroke or death rate was 1.5%. The 30-day stroke rate was 1.1%. The 2 deaths in the study were not stroke related. Conclusions: Low death, stroke, or MI rates were demonstrated with GCS in patients at high risk for CEA. The 30-day stroke rate of 1.1% suggests that the carotid stent mesh covering may reduce the neurologic events associated with CAS when used in appropriately selected patients.

Original languageEnglish
Pages (from-to)2396-2404
Number of pages9
JournalJACC: Cardiovascular Interventions
Volume11
Issue number23
DOIs
StatePublished - Dec 10 2018

Keywords

  • GORE carotid stent
  • carotid artery disease
  • carotid artery stent
  • carotid endarterectomy
  • clinical studies
  • high risk
  • stent design/structure/coatings
  • stroke

Fingerprint

Dive into the research topics of 'A First-in-Human Evaluation of a Novel Mesh-Covered Stent for Treatment of Carotid Stenosis in Patients at High Risk for Endarterectomy: 30-Day Results of the SCAFFOLD Trial'. Together they form a unique fingerprint.

Cite this