Skip to main navigation Skip to search Skip to main content

A batch membrane reactor for laboratory studies

  • SUNY Buffalo

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

A membrane reactor consisting of two recirculating flow systems connected via a membrane module has been constructed and used to study the dehydrogenation of cyclohexane. When the reactor is operated differentially it is possible to obtain the same information that is generated when using more conventional steady flow reactors. The batch system has the advantages of easily varying the ratio of membrane area to reactor volume and sampling a very wide range of effective Damkohler numbers. These are important variables in design studies. This ability has been demonstrated for the dehydrogenation of cyclohexane. The batch system reproduced results from studies using a more conventional flow reactor. In addition, with the batch reactor it was possible to experimentally confirm predictions that were based upon computer simulation but which were outside the range of experimental study for the conventional reactors used.

Original languageEnglish
Pages (from-to)93-100
Number of pages8
JournalJournal of Membrane Science
Volume118
Issue number1
DOIs
StatePublished - Sep 4 1996

Keywords

  • Dehydrogenation
  • Glass membranes
  • Membrane reactor

Fingerprint

Dive into the research topics of 'A batch membrane reactor for laboratory studies'. Together they form a unique fingerprint.

Cite this