A 3-dimensional stationary cascade gamma-ray coincidence imager

  • Xiao Liu
  • , Hui Liu
  • , Li Cheng
  • , Jing Wu
  • , Tianwei Bao
  • , Rutao Yao
  • , Yaqiang Liu
  • Tsinghua University
  • Ministry of Education of the People's Republic of China
  • Beijing Normal University
  • CAS - Institute of High Energy Physics

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

Objective. For certain radionuclides that decay through emitting two or more gamma photons consecutively within a short time interval-called cascade gamma-rays, the location where a radiopharmaceutical molecule emits cascade gamma-rays can be identified through coincidence detection of the photons. If each cascade photon is detected through a collimation mechanism, the location of the molecule can be inferred from the intersection of the back-projections of the two photons. Approach. In this work, we report the design and evaluation of a three-dimensional stationary imager based on this concept for imaging distributions of cascade-emitting radionuclides in radiopharmaceutical therapy. The imager was composed of two gamma-ray cameras assembled in an L-shape. Both cameras were NaI(Tl) scintillator based, one with a multi-slit collimator, the other with a multi-pinhole collimator. The field of view (FOV) was 100mm(o) × 100mm(L). Based on the unique characteristics of the cascade coincidence events, we used a direct back-projection algorithm to reconstruct point source images for assessing the imager's intrinsic spatial resolution and the standard maximum likelihood expectation maximization algorithm for reconstructing phantom images. Main results.Weevaluated the performance of the imager in both simulated and prototype form with radionuclide 177Lu (cascade photon emitter).On the simulated imager, the coincidence detection efficiency at the center of FOVwas 3.85 × 10-6, the spatial resolution was 7.0 mm. Onthe prototype imager, the corresponding values were 3.20 × 10-6 and 6.7 mm, respectively. Simulated hot-rod and experimental cardiac phantom studies demonstrate the first three-dimensional cascade gamma coincidence imager is fully functional.

Original languageEnglish
Article number225001
JournalPhysics in Medicine and Biology
Volume66
Issue number22
DOIs
StatePublished - Nov 21 2021

Keywords

  • Cascade gamma-rays
  • Coincidence imaging
  • Lutetium-177
  • Radiopharmaceutical therapy