Skip to main navigation Skip to search Skip to main content

13C-breath tests for sucrose digestion in congenital sucrase isomaltase-deficient and sacrosidase-supplemented patients

  • Claudia C. Robayo-Torres
  • , Antone R. Opekun
  • , Roberto Quezada-Calvillo
  • , Xavier Villa
  • , E. O. Smith
  • , Marilyn Navarrete
  • , Susan S. Baker
  • , Buford L. Nichols
  • Baylor College of Medicine
  • Universidad Autonoma de San Luis Potosi
  • University of Texas Medical Branch at Galveston

Research output: Contribution to journalArticlepeer-review

44 Scopus citations

Abstract

BACKGROUND: Congenital sucrase-isomaltase deficiency (CSID) is characterized by absence or deficiency of the mucosal sucrase-isomaltase enzyme. Specific diagnosis requires upper gastrointestinal biopsy with evidence of low to absent sucrase enzyme activity and normal histology. The hydrogen breath test (BT) is useful, but is not specific for confirmation of CSID. We investigated a more specific C-sucrose labeled BT. OBJECTIVES: Determine whether CSID can be detected with the C-sucrose BT without duodenal biopsy sucrase assay, and if the C-sucrose BT can document restoration of sucrose digestion by CSID patients after oral supplementation with sacrosidase (Sucraid). METHODS: Ten CSID patients were diagnosed by low biopsy sucrase activity. Ten controls were children who underwent endoscopy and biopsy because of dyspepsia or chronic diarrhea with normal mucosal enzymes activity and histology. Uniformly labeled C-glucose and C-sucrose loads were orally administered. CO2 breath enrichments were assayed using an infrared spectrophotometer. In CSID patients, the C-sucrose load was repeated adding Sucraid. Sucrose digestion and oxidation were calculated as a mean percent coefficient of glucose oxidation averaged between 30 and 90 minutes. RESULTS: Classification of patients by C-sucrose BT percent coefficient of glucose oxidation agreed with biopsy sucrase activity. The breath test also documented the return to normal of sucrose digestion and oxidation after supplementation of CSID patients with Sucraid. CONCLUSIONS: C-sucrose BT is an accurate and specific noninvasive confirmatory test for CSID and for enzyme replacement management.

Original languageEnglish
Pages (from-to)412-418
Number of pages7
JournalJournal of Pediatric Gastroenterology and Nutrition
Volume48
Issue number4
DOIs
StatePublished - Apr 2009

Keywords

  • 13C-breath test
  • Congenital sucrase-isomaltase deficiency
  • Glucose oxidation
  • Sacrosidase supplementation
  • Sucrose digestion

Fingerprint

Dive into the research topics of '13C-breath tests for sucrose digestion in congenital sucrase isomaltase-deficient and sacrosidase-supplemented patients'. Together they form a unique fingerprint.

Cite this